Available in high-performance two-speed versions. They are less bulky than large in-line centrifugal fans and can be installed in loft spaces or service shafts. This range is specially designed for residential applications requiring remote extraction. It is also supplied with a mounting bracket for quick and easy installation on wooden joists and panels. The inlet/outlets are compatible with flexible and rigid pipe runs up to 3m either side of the fan (6m). The units operate manually from an (optional) three-position switch (off/low/high)
Application
Aventa 125mm fans are suitable for removing damp moist air, odours and airborne pollutants from bathrooms, en-suites, shower rooms, utilities, kitchen and other internal living spaces without windows or natural ventilation.
Main Features
Timer | No |
Product Category | In-Line Fans |
Round System (mm) | 125 |
Product Type | Mixed Flow In-Line Fan |
Product Group | Ventilation Fan |
Spigot size (mm) | 123 |
IP Rating | IPX4 |
Power Min (Watts) | 23 |
Power Max (Watts) | 37 |
Decibel Rating (dB) - Low | 61 |
Decibel Rating (dB) - Max | 78 |
Colour | White |
Weight (Kg) | 1.4 |
Packaged Weight (Kg) | 1.8 |
Packaged Length (mm) | 210 |
Packaged Width (mm) | 195 |
Packaged Height (mm) | 260 |
Barcode | 05019009305462 |
Barcode - Type | GTIN |
Manufacturer Product Code | 9041087 |
Vent Axia (similar) | ACM125 |
Manrose (similar) | MF125S |
Greenwood Airvac (similar) | SD100 |
Airflow Performance (l/s) - Low | 61 |
Airflow Performance (l/s) - High | 78 |
Airflow Performance (m³/h) - Low | 220 |
Airflow Performance (m³/h) - High | 280 |
Warranty (Years) | 3 |
Quick Search: | QS18903 |
Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
We are proposing to install a continuous ventilation system to serve the kitchen and adjoining tibet. The kitchen extract we are intending to locate about 5m away from the hob which will have a standard recycling over hood extract unit.
Hello Robert
Thank you for your question. How long are both the duct runs together as this fan will only do a 6mtr straight run. If you could give me a call on 0208 463 9683 I will be happy to go though your requirements with you.
Kind Regards
Anita
I am hoping to use one of these fans for a cooker hood extraction with a long pipe run. Will these fans withstand the high temperatures involved or do I need an all-metal one.?
Hello John
Thank you for your question. Do you know what the temperature would be. As the temperature of the transferred air must not exceed 40degree c on most of the in-line fans. If I can help any further please do not hesitate to contact me on 0208 463 9683.
Kind Regards
Anita
Please advise product ref for 125mm single speed in line fan with adjustable run on time
Hello John
Thank you for your question. The units operate manually from an (optional) three position switch (off/low/high) or with adjustable timer version (1 to20 minutes) The model number for the timer in-line fan is QS18904
|
|