Key Features & Customer Benefits of the FireCuff - Restores and maintains integrity of 30 & 60 minute fire rated ceilings.
- Sleeve can be fitted in seconds.
- No mastic, screws or support required.
- Sleeve is out of sight once the fan or vent is fitted.
- Sleeve can be fitted from above or below the ceiling.
- Easy to retrofit to existing fans and vents.
- Provides an effective acoustic barrier between fan and ceiling,
- Limiting noise from vibration.
Extractor Fans and ventilation ducting are widely used in domestic and commercial buildings and are often installed in the ceiling. Ceilings are subject to fire regulations and must be fire protected in accordance with Approved Document B of the Building Regulations. Once a hole is made in the ceiling for the installation of a thermoplastic fan or vent, the integrity of the ceiling and its ability to perform in the event of a fire is significantly reduced. To reinstate the original fire rating of the ceiling a suitable fire stop must be fitted. The popularity of forced and controlled ventilation is increasing as it can be much more energy efficient than traditional ventilation methods. The use of centralised ventilation units and heat recovery units result in the building being subject to penetration holes through the structure, creating pathways for the passage of both fire and smoke. The ability of the fire to move all around the building via the ventilation system makes it ever more important to protect all ceiling mounted fans and vents. Code | Description | To fit Fan/Vent | Hole Size | DUCFC080 | 80mm FireCuff | 80mm | 102mm | DUCFC100 | 100mm FireCuff | 100mm | 127mm | DUCFC125 | 125mm FireCuff | 125mm | 162mm | DUCFC150 | 150mm FireCuff | 150mm | 193mm | Code | Description | To fit Fan/Vent | Hole Size | DUCFC080 | 80mm FireCuff | 80mm | 102mm | DUCFC100 | 100mm FireCuff | 100mm | 127mm | DUCFC125 | 125mm FireCuff | 125mm | 162mm | DUCFC150 | 150mm FireCuff | 150mm | 193mm |
Watch Isells Plastic Ducting Channel - Watch video | Code | Description | To Fit Fan/Vent | Hole Size | | DUCFC080 | 80mm FireCuff | 80mm | 102mm | | DUCFC100 | 100mm FireCuff | 100mm | 127mm | | DUCFC125 | 125mm FireCuff | 125mm | 162mm | | DUCFC150 | 150mm FireCuff | 150mm | 193mm |
Test Data | 30 minute plasterboard / timber ceiling | 60 minute plasterboard /timber ceiling | | Duration of effective protection - 36 mins | Duration of effective protection - 72 mins | | Test Standard - W476 Part 21 | Test Standard - BS476 Part 21 | | Test No - ChiltilFO6015 | Test No - ChiltiF06021
|
|