The revolutionary Vent-Axia LuminAir Safety Extra Low Voltage fan and light in a single ceiling mounted fitting.
The IPX7 unit is installed directly over a shower in complete safety. Vent-Axia LuminAir extracts moisture and humidity at source, preventing damaging condensation from spreading. At the same time it bathes the shower enclosure in a rich soft light - bringing any dark shower to life. Ideal for all types of bathroom and shower applications, and is particularly suitable for bedsit and en-suite shower installations. 
European Patented No. EP0730716 Australian Patent No. 677461 South African Patent No. 94/8865 Other world patents applied for Designed for mounting in a wide variety of ceiling thicknesses. The safety isolating transformer to BS EN 60742 is mounted in a purpose made enclosure that can be wall mounted or sited in the loft, and is designed to accept mini trunking (LuminAir L transformer - IP20 - loft mounted). LuminAir has a 20 Watt 40° spread, pre-formed Dichroic Multi-MirrorTM lamp, to give a pool of soft warm light. The lamp has a long life and is simple to change. 
LuminAir Ventilation Kit LuminAir L, T or H SELV fan and light, choice of bezel, 90° bend, 3m of flex-duct, wall grille and cable ties. LuminAir Shower Ventilation Kit L LuminAir L - Fan & light. Provides simultaneous fan and light operation from the bathroom light switch. Stock Ref. No. 18 81 10 LuminAir Shower Ventilation Kit T LuminAir T (Timer) - Fan & light. Switches the fan On with the light. When the light is switched Off, the fan continues to run for an adjustable set period to meet the building regulations for internal bathrooms. Stock Ref No. 18 82 10 LuminAir Shower Ventilation Kit H LuminAir H (Humidity) - Fan & light. Combines a light activated by the bathroom light switch and an Ecotronic Humidity Sensor which will switch the fan ‘On' whenever the humidity level warrants. Stock Ref. No. 18 86 10 Supply to the LuminAir transformer 220-240V/1/50Hz. Output to LuminAir 12V SELV/1/50Hz. Safety isolating transformers conform to BS EN 60742. Stylish Chrome or Gold Bezels are also available. 
| Type | Stock Ref. No. White | Stock Ref. No. Chrome | Stock Ref. No. Gold | Amps @240V |
|---|
LuminAir Ventilation Kit L | 45 34 10 | 45 34 11 | 45 34 12 | 0.2 | LuminAir Ventilation Kit T | 45 34 13 | 45 34 17 | 45 34 18 | 0.2 | LuminAir Ventilation Kit H | 45 34 16 | 45 34 17 | 45 34 18 | 0.2 | | | | | | LuminAir Turbo SKL | 45 34 19 | 45 34 20 | 45 34 21 | 0.3 | LuminAir Turbo SKT | 45 34 22 | 45 34 23 | 45 34 24 | 0.3 |
| Type | Free Air Extract Performance | Max Watts | dB(A) @ 3m |
|---|
| m³/h | l/s |
|---|
LuminAir Ventilation Kit L | 110 | 31 | 40 | 35 | LuminAir Ventilation Kit T | 110 | 31 | 40 | 35 | LuminAir Ventilation Kit H | 110 | 31 | 40 | 35 | | | | | | LuminAir Turbo SKL | 160 | 44 | 35 | 38 | LuminAir Turbo SKT | 160 | 44 | 35 | 38 |

| | A | B | C | D | F |
|---|
| LuminAir Kit | 150 | 180 | 139 | 98 | 10 | | *Transformer (T&H) | 175 | 90 | 55 | 30 | | | Transformer (L) | 83 | 76 | 70 | 61 | | | Humidity Sensor | 87 | | 33 | | | | Fixing hole diameter 110mm | | | | | |
 For upgrading existing extract systems or to provide multiple extract points to a central fan. The Vent Light consists of a LuminAir Safety Extra Low Voltage (SELV) light with white ceiling bezel and 90° bend. The bend is especially suitable for connection to extract ductwork runs between joists. On/Off operation is via the bathroom light switch. Gold and silver bezels are available as accessories. Stock Ref. No. 45 33 95 - White


LuminAir Turbo Ventilation Kit For applications where a more powerful system is required. The kit comprises a LuminAir Turbo L or T mains fan and SELV light, choice of bezel, 90° bend, 6 metres of flexible duct, quick fix wall grille and four cable ties. Meets Building Regulations (Document F) performance assuming ductwork provided is fully extended and one 90° bend. LuminAir Turbo SKL Provides simultaneous On and Off operation of the fan and light from the bathroom light switch. LuminAir Turbo SKT Switches the fan On with the light. When the light is switched Off, the fan continues to run for an adjustable fixed period to meet the Building Regulations for internal bathrooms. 
| | A | B | C | D | E | F |
|---|
| Vent Light | 150 | 180 | 10 | | | | Turbo Fan | 100 | 132 | 105 | 136 | 70 | 145 | Fixing hole diameter 110mm | | | | | | | |
Vent Light and Bend Turbo Fan
 
Supply and install a Luminair in-line fan and light kit combination as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: 01293 526062. When installed the light complies with the 16th edition of IEE Regulations (BS7671), 2001) and an on site guide for Safety Extra Low Voltage (SELV) operation. The transformer should be safety insulating to BS EN 60742. The fan and transformer should be BEAB Approved. The fan should meet the installed performance of the Building Regulation (Document F) Requirements - 15 litres a second for bathrooms and 6 litres for toilets, (15 minute timer overrun model for internal rooms). The motor should be manufactured with self aligning sleeve bearings and fitted with Standard Thermal Overload Protection, (S.T.O.P.) the motor should be insulated to Class B. Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used. Supply and install a Luminair Safety Extra Low Voltage (SELV) in line fan and light combination as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone 01293 526062. When installed the fan complies with the 16th edition of IEE Regulations (BS7671), 2001) and an on site guide for Safety Extra Low Voltage (SELV) operation. The transformer should be safety insulating to BS EN 60742. The fan should be rated to IPX7. The fan and transformer should be BEAB approved. The fan performance should meet the Building Regulation (Document F) requirements. The motor should be manufactured with self aligning sleeve bearings and fitted with Standard Thermal Overload Protection, (S.T.O.P.) the motor should be insulated to Class B and designed to operate on SELV 12V/1/50Hz. FAQs Answered: • The max. length of 1.5mm2 cable between Transformer and fan is 8 metres. • All controls are included, no extra sensors needed. • Roof, wall and soffit terminations can be used. • Clearance above the ceiling for the fan and light model must be at least 180mm when using the 90° bend. • Maximum 20W sealed lamp to be used (as supplied).
|