<< Close Menu
Close Menu >>
Top » Ventilation Fans » Ventilation - In Line Fans

VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER

Model: VENACM150T
Search: QS3094
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
  • VENT AXIA ACM150T IN LINE FAN 150MM THREE SPEED WITH TIMER
Availability: In Stock
List Price: £581.60
Only: £264.36 Inc VAT
  • DETAILS

    VENT AXIA ACM150T (17106020)

    Mixed Flow Inline Duct Fan with timer for 150mm ducting.

    In Line Mixed Flow fans offer two and half times the pressure of conventional axial fans, are dimensionally more compact making them ideal for many ducted applications. The impeller blade design with guide vanes provides optimum pressure characteristics and simple connectivity and quieter more efficient running provides the complete solution.

    The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions and can be mounted to meet its optimum performance.

    Features & Benefits

    • Market leading performance
    • Incredibly quiet operation
    • Designed and manufactured in UK
    • Three speed selectable motor
    • Timer version
    • Please note Vent Axia ACM Timer Models are not compatible with speed controllers
    • Removable motor core assembly
    • Rotating motor chassis assembly
    • Compatible with the extensive i-sells.co.uk Ducting Range (Ducting Not Included)
    • IP44 rated
    • Aesthetically pleasing construction with wipe clean polymer casing

    Range Product Specification

    Motor

    All motors are fitted with Standard Thermal Overload Protection. (S.T.O.P.). Designed for ambient temperatures up to +50°C.

    Size 100 and 125 with shaded pole motors. Size 150, 200, 250 and 315 with capacitor start and run motors. All sizes are Class II appliances except ACM250 and ACM315 which is Class I Supply voltage 220-240V/1/50Hz.

    Typical Range Specifications

    Supply and install the ACM range of commercial In-line fans as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: 01293 526062.

    The fan should be of the mixed flow design specifically for use with rigid and flexible ducting with energy efficiency and low sound levels in mind. The fan shall be fitted within the ducted system and isolated from the building structure by means of Anti- Vibration mountings.

    The fans should be dimensionally compact saving weight and installation costs. The casing should be manufactured from galvanised sheet steel and manufacture is controlled to BS EN ISO 9001.

    The fan motor should be removable by means of 2 Clip Bands for ease of maintenance.

    Motors should have ball bearings greased for life to allow the fan to be installed at any angle and should have Class B insulation to allow the fan to work satisfactorily in ambient air temperatures from -5°C to +50°C and should be fitted with Standard Thermal Overload Protection (S.T.O.P.).

  • FEATURES

    Features

    • Timer version
    • Quietest on the market
    • Designed and manufactured in UK
    • Rotating motor chassis assembly
    • Compatible with the extensive i-sells.co.uk Ducting Range(Ducting Not Included)
  • TECHNICAL

    Technical Specifications

    Timer Yes
    Product Category In-Line Fans
    Round System (mm) 150
    Product Type Mixed Flow In-Line Fan
    Product Group Ventilation Fan
    Length (mm) 268
    Width (mm) 210
    Height (mm) 365
    Spigot size (mm) 147
    IP Rating IP44
    Power Min (Watts) 42
    Power Max (Watts) 48
    Decibel Rating (dB) - Low 31
    Decibel Rating (dB) - Max 35
    Colour White
    Weight (Kg) 2.94
    Packaged Weight (Kg) 2.94
    Packaged Length (mm) 268
    Packaged Width (mm) 210
    Packaged Height (mm) 365
    Economy Delivery Not Eligible
    Manufacturer Product Code 17106020
    Vent Axia (similar) ACM150T
    Manrose (similar) MF150T
    Airflow Performance (l/s) - Low 123
    Airflow Performance (l/s) - High 145
    Airflow Performance (m³/h) - Low 442
    Airflow Performance (m³/h) - High 522
    Warranty (Years) 2
    Quick Search: QS3094
  • REVIEWS
      Rated 5/5 based on 1 customer reviews
      Add Your Review
    1. Colin Lawson
      5 / 5 stars
      Date Added: Friday 05 August, 2016
      very good product that can easily removed for maintenance
  • Q & A

    Product Questions

    Questions and Answers, do you need more information about this product?

    Ask a Question

    Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.

    #1
    Pipe Length

    How many meters of inlet and outlet pipe can be used on this fan.

    Question by Graeme, 02-11-2015

    Hello Graeme

    Thank you for your question. This fan does a 6mtr straight run without any bends. 

    Replied by i-sells, 02-11-2015
    #2
    ducting length and fan positioning

    I've seen a question answered on this site confirming this fan will be sufficient for 6m ducting with no bends. We would like to install this fan to serve a cooker hob, with a filter grill fitted at source. The ducting and fan would be situated within an existing chimney, with the fan located about 2m above hob in an accessible hatch and the ducting outlet at the roof level with a cowl installed. The total ducting length is about 5m. Question is, is the fan location close enough to source to draw moisture, noting there will be an existing draw from chimney. Your thoughts on this would be helpful. Thanks

    Question by Sam, 03-10-2016

    Hello Sam

    Two metres should be fine as the installation instructions recommend at least one metre distance from the extract point.
    To access these double click on the product image to expand the page and look to the right where there is a 'download product pdf's' option giving installation and wiring instructions.
    I hope this helps.
    Regards
    Ian

    Replied by i-sells, 03-10-2016
    #3
    Fan as supply

    Can this fan be ducted in line and provide a space with fresh air supplied from outside? Thanks

    Question by Stu, 21-10-2016

    Hello Stu,

    You could indeed use this fan to supply outside air to a location. This is quite a common usage of the product when trying to ventilate areas without easy access to fresh air, such as internal rooms of a flat.

    Depending on your intention, you may find that the 'Standard' model without overrun timer is also of use. The product links are as follows:

    Standard Model (Without timer)

    Timer Model (Overrun Timer)

    Please do not hesitate to contact me if you have any other questions.

    Kind regards,

    Michael

    Replied by i-sells, 21-10-2016
    #4
    Fan & stat

    Hi, I'm looking to put a in line fan in a loft space to extract heat from my comms cupboard, but want to put it on a thermostat so it comes on when temp reaches 27C. Have you a stat that goes with this fan or any over. Many thanks.

    Question by Wes, 23-10-2016

    Hello Wes

    I don't know of a fan that has thermostat control options but that is not to say one doesn't exist.
    I would probably recommend the Manrose MF100S, as it is compaible with a switch, humidistat and PIR sensor, although this doesn't have a thermostat option it can be set to run on a constant trickle speed which may be enough to stabilise the comms cupboard temperature.
    It may also be worth contacting an electrician to see if a thermostat is compatible, after all it is only another form of switch?
    Please be aware however, that if any make of fan is connected to a non approved control which causes breakdown or failure the guarantee is likely to be null and void.

    Replied by i-sells, 24-10-2016
    #5
    Vent-Axia in line 150 + 150T

    Good Afternoon Please could you supply the m3/hr and the maximum flexible/rigid ducting. Thank you. Richard Darke

    Question by Richard, 22-10-2019

    Hello Richard


    Thank you for your question. The duct run for this fan is 8mtrs straight or 6mtr with two bends. The l/s this fan will do is Low: 123l/s  and High: 145l/s. If I can help any further please do not hesitate to contact me

    Kind Regards
    Anita

    Replied by i-sells, 22-10-2019
  • DELIVERY
    Delivery: You'll receive in: Cost Min Order
    Free Delivery 3 to 5 Days FREE £100
    Standard 2 to 4 Days £4.99 -
    Express Courier Next day+ £9.95 Any

    View Full Delivery Info

    FREE Delivery for orders over £100 inc VAT.

    + Order before noon for Next Working Day Delivery for items in stock

    Excludes Highlands, Islands, and Certain Postcodes.

    Please Note:
    Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.

View Product on Full Website

You may also like

  1. List Price: £300.68
    Only: £164.47
  2. List Price: £237.48
    Only: £63.06
  3. List Price: £312.44
    Only: £122.84
  4. List Price: £146.99
    Only: £49.57
  5. List Price: £298.34
    Only: £106.60
  6. List Price: £429.76
    Only: £119.87

View similar products in category:
Ventilation - In Line Fans

Previous / Next Product