Top » Ventilation Fans » Ventilation - Heat Recovery

Vent Axia Sentinel Kinetic Plus B Whole House Heat Recovery Unit (443028)

Model: VEN443028
Search: QS9710
  • Vent Axia Sentinel Kinetic Plus B Whole House Heat Recovery Unit (443028)
  • Vent Axia Sentinel Kinetic Plus B Whole House Heat Recovery Unit (443028)
Availability: 2 to 7 days
List Price: £3,594.06
Only: £1,158.00 Inc VAT
  • DETAILS

    SENTINEL KINETIC PLUS B

     

    High efficiency, SAP Appendix Q eligible, residential/light commercial Mechanical Ventilation with Heat Recovery unit.

    With Summer Bypass and Integral Humidistat.

    The Sentinel Kinetic incorporates:
    A whole-house heat recovery system with up to 92% energy
    efficiency.

    Features and Benefits

    • Manufactured in the UK
    • Building Regulations Part F compliant
    • SAP Appendix Q Eligible
    • Energy savings trust best practice compliant
    • Up to 92% heat recovery whilst controlling condensation
    • Programmable Summer bypass
    • Left or right-hand installation
    • Horizontal and/or vertical duct outlets
    • Integrated digital controller for simple and accurate commissioning
    • Lightweight for easy installation
    • External condensate connection
    • Plug and play controls; Humidistat, Vent-Wise, Wireless remote
    • BMS connectivity
    • LS inputs. (Light switch)
    • Volt-free inputs
    • Self-diagnosis for simplified fault finding
    • Multiple switching options: Light switch, PIR, Humidistat etc
    • Adjustable delay on/delay off timer
    • Easy access G3 filters

    An easily accessible heat recovery cube protected by
    two removable EU3 filters. Two Lo-Carbon Energy Saving EC DC
    fans ensure long life (typically over double the life of AC motors)
    and the lowest possible energy use. Fully insulated construction with
    built-in condensation drain. Fitted with 150mm spigots.
    Specifically designed for new build homes and light commercial/multiple residential properties with a high level of insulation.
    Lo-Carbon Sentinel Kinetic meets the latest requirements of the Building Regulations Document F 2010 for whole-house system ventilation: System 4. Continuous mechanical supply and extract with heat recovery.

     

    Range Product Specification

    The Lo-Carbon Sentinel Kinetic Plus has 2 fully adjustable speeds and a purge setting - maximum. On the front of the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.

    The Sentinel Kinetic Plus models can be mounted vertically in a roof space or on a suitable wall. When mounted in an unheated area ducting should be insulated. Ducting can be attached to the unit horizontally, vertically or both.
    Left or right-hand installation. The unit is supplied with duct spigots to outside on the right-hand side. These can be reversed on-site by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel.
    Horizontal and vertical spigots: The combination of spigot options allows installation in confined locations. If a vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied.
    Condensate drain can be taken out through the back, bottom or front of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.

    Typical Range Specifications

    Performance: m³/h l/s
    Max ventilation rate 400 at 150Pa 111
    N° speed settings 3 (variable between 10% and 100%)  

    Efficiency: The unit should retain up to 92% of the temperature differential of outgoing air.

    Heat exchanger: should be of a multi-plate counter-flow type constructed out of PETG with ultrasonically welded joints.

    Motor: Should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.

    Fan: The fan impeller should be of a backward curved centrifugal type, dynamically balanced.

    Controls: The unit should contain an integral driver circuit permits connection to Switched Live, No-volt and 0v to 10v Proportional Input.

    Ducting spigots: The unit should provide 150mm ø x 50mm long spigots for all duct connections with vertical and horizontal locations. (Can be converted to flat ducting).

    Filter: should be synthetic material tested to a minimum of EU3.

    Condensation: The outlet provided should offer front, rear and bottom connections external to the unit.

    Construction: The unit outer case should be constructed of white ABS. The heat exchanger access doors should give tool-free access to the filters.

    Mounting: Vertical, floor or wall-mounted, or within a cupboard.

    Mains electrical supply: 230VAC 50Hz.

    Complies to the following approvals/directives: CE, LVD, EMC. SAP Appendix Q eligible.

    Click the link below to be taken to the replacement filters for the Vent Axia Sentinel Kinetic Plus B Whole House Heat Recovery Unit. 

    Vent Axia Spare G3 Filter Pack For Vent Axia Kinetic Plus/Plus E 403702

  • TECHNICAL

    Technical Specifications

    Product Category Heat Recovery Unit
    Product Type Heat Recovery - Whole House
    Product Group Ventilation Fan
    Product Variety Plus B
    Spigot size (mm) 150
    Voltage (V) 220-240
    Decibel Rating (dB) - Max 39
    Temp Max (°C) 45
    Temp Min (°C) -20
    Warranty (Years) 5
    Quick Search: QS9710
  • REVIEWS
  • Q & A

    Product Questions

    Questions and Answers, do you need more information about this product?

    Ask a Question

    Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.

    #1
    Clean fan blades?

    How to get past the summer by pass unit to clean the fan blades, because I have started to notice a low "hum" in operation ( I believe this is the most likely cause of noise ?)

    Question by Robert Johnson, 06-07-2020

    Hello Robert


    Thank you for your question. Please see below Vent Axia's number to give their technical department a call. They will be back in the office tomorrow 9am - 4pm. As they will be able to help you further.

    Vent Axia: 0344 856 0590

    Kind Regards
    Anita 

    Replied by i-sells, 06-07-2020
  • DELIVERY
    Delivery: You'll receive in: Cost Min Order
    Free Delivery 3 to 5 Days FREE £100
    Standard 2 to 4 Days £4.99 -
    Express Courier Next day+ £9.95 Any

    View Full Delivery Info

    FREE Delivery for orders over £100 inc VAT.

    + Order before noon for Next Working Day Delivery for items in stock

    Excludes Highlands, Islands, and Certain Postcodes.

    Please Note:
    Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.