Kair Cowl Vent 100mm - 4 inch Stainless Steel Grille with Backdraft Shutter to Protect Against Insects & Wind Noise
-
DETAILS
Kair Cowl Stainless Steel Grille 100mm - 4 inch Vent Cover
Product Details:
Featuring an integrated non-return backdraft damper and supplied with screws and cowl-to-wall rubber gasket, this stylish steel wall extractor hood vent outlet has an unobtrusive profile.
Manufactured from Grade 304 Stainless Steel
A cushioned low noise flap prevents unwanted sounds from being heard from within the property.
This also features a gravity flap to prevent small mammals and birds from accessing the ducting attached to it.
The gravity flap is stylishly covered by the square shape cowl and in doing so, offers more of an aesthetic appearance than most traditional plastic grilles.
Stainless steel Cowles offer greater weatherproofing, and are not affected by ultraviolet rays like some plastics can be.
The grille can be cleaned using any stainless steel cleaner.Ideal for all tumble dryer vent pipes / hoses, bathroom vents & extractors, air conditioning units, kitchen fans & vents, home wall vents, heat transfer & ventilation systems, gas & electric dryers, cooker hood extractors, as well as a wide variety of industrial uses.
-
FEATURES
Features
- Superior alternative to plastic cowls.
- Cushioned noise disturbance reduction flap.
- Ideal for both domestic and commercial extract applications.
- Integral back draft shutter (damper).
- Contains a weatherproof seal to eliminate leaks and drafts.
-
TECHNICAL
Technical Specifications
Product Category Grilles Round System (mm) 100 Product Type Grille - Cowled Outlet Product Group Metal Ducting Length (mm) 150 Width (mm) 150 Height (mm) 126 Spigot size (mm) 96 Free Area (mm²) 6,221 Colour Silver Material Stainless Steel Weight (Kg) 0.316 Packaged Weight (Kg) 0.32 Packaged Length (mm) 150 Packaged Width (mm) 150 Packaged Height (mm) 135 Temp Max (°C) 60 Temp Min (°C) -15 Barcode 5060272544249 Quick Search: QS133 -
REVIEWS
-
Louise WhiteDate Added: Tuesday 06 December, 2022
Just what I needed for dryer ductwork. Quality product. -
Neil DouglasDate Added: Wednesday 10 November, 2021
Good quality gear at a good price and very rapid delivery. Would certainly use this company again. -
Ian ThomasDate Added: Wednesday 01 September, 2021
Haven't installed yet but looks good and appears well made. -
Jeff ParkinDate Added: Thursday 06 May, 2021
Just what I wanted.... -
Jeff ParkinDate Added: Thursday 06 May, 2021
Just what I wanted.... -
Andrew LondonDate Added: Tuesday 05 May, 2020
Great product, but if you have a straight wall the door doesn't stay closed when there is no air coming out of your extractor fan, it just knocks every few seconds and is really annoying. -
Tim FeestDate Added: Saturday 16 March, 2019
This was purchased to replace an old, and in windy conditions very noisy, plastic vent. Installation was a simple matter; and whilst the non-return flap in the new vent does make a noise when it's windy (reflected in the four-star rating: if I could do so I'd give it four-and-a half) it's a lot quieter than the old one. The vent looks very smart and being stainless steel this won't suffer UV degradation as did the plastic one 9and should be easy to clean when the time comes). Overall, pleased with the product and very pleased with the service from i-sells. -
Matthew RobinsonDate Added: Friday 21 December, 2018
looks great, would be 5 stars where not for fact it came with 2 screws not 4 and no fixings at all. -
Date Added: Sunday 23 July, 2017
The Exterior of the vent is fine and well made but the hinged part of the flat was flimsy. The unit had to be tilted to about 80 degrees to make the flap close. I fiddled with the hinge and the flap stayed open at the vertical angle. I didn't want to bother posting it back because I suspected that a replacement might not be any better. I decided to install it at this non vertical angle as it is at the top of the house and no-one will notice. I had to put a spacer under it and put extra mortar in over the bottom open aspect. If you purchase, ask the supplier to check that the flap closes at vertical 90 degree angle.
-
-
Q & A
Product Questions
Questions and Answers, do you need more information about this product?
Ask a QuestionYour question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
#1100MM COWLED OUTLET WITH NON-RETURN FLAP STAINLESS STEEL DUCTING VENT / GRILLEIs the non-return flap in this item (model DUCSS103) spring loaded or does it rattle in windy weather?
Question by Michael Gibb, 18-08-2015Hello Michael
Thank you for your question
The Damper flap is attached by a wire hinge and is designed to close with the aid of gravity this means it is only suitable for wall mounted applications.
Replied by i-sells, 08-07-2016#3100MM COWLED OUTLET WITH NON-RETURNWould this be suitable to provide air flow for a gas fire or does the flap require a fan to push the flap open?
Question by Jim, 30-11-2015Hello Jim
Thank you for your question. This item does require air to open the flap. We recommend a black hole ventilator for gas fires if you know how much free air is required. Here are two options for you.
QS2851, QS2847
Replied by i-sells, 30-11-2015#4does the flap close 90 degree angellooking at the reviews - I can see that this is cowl is not flat to the wall but does the hinge shut at 90 degrees
Question by mandy, 08-08-2019Hello Mandy
Hopefully I have understood the question?This is a weather cowl (protection from wind and rain) and the flap is opened by air pressure from a powered fan, when the fan is not operating the flap will close by means of gravity. If your question regarding "90 degrees" means your intention is to rotate the cowl to the left or right, the flap would not close.Replied by i-sells, 08-08-2019#5Inlet or outlet?Is this an inlet vent or outlet? Which direction does the valve allow airflow?
Question by Simon, 13-03-2020Hello Simon
Thank you for your question. This vent is for external use only. The cowl is designed for the wind to bounce off and there is a damper within the cowl to stop the blow back of air. If you could advise me of your application i will advise you furtherKind RegardsAnitaReplied by i-sells, 13-03-2020#6required sizeHi , I have an issue with water penetrating a plastic covered vent over a window in a bathroom , is the 100mm referring to the outside square or the pipe diameter ? its to go on a bather extractor .
Question by jeremy, 08-07-2020Hello Jeremy
Thank you for your question. The 100mm refers to the spigot on the back of the grille which fits into 100mm ducting pipe as the pipe is female and the spigot on the grille is male. If I can help any further please do not hesitate to contact meKind ReagrdsAnitaReplied by i-sells, 08-07-2020#7Can kair cowl be used for tumble drierWe need to make a vent for a tumble drier out to a North wall and it is a cold windy place. Will the kair cowl with back draft shutter be ok for this use. i mean will the damp air from the tumble drier be able to escape OK?
Question by Diana Ray, 27-04-2021Hello Diana
Thank you for your question. Yes this item will be fine for your application as the damper will open when the dryer is on so the air will extract to the outsideKind RegardsAnitaReplied by i-sells, 28-04-2021#8Quick Search: QS133Can you please confirm that this product is suitable and safe to use with a commercial size tumble dryer, where to use a plastic Vent would be a fire-hazard?
Question by Sara, 25-06-2021Hi Sara,
Many thanks for your enquiry today. In answer to your question yes this should be fine for a commercial tumble dryer. i would recommend using the correct size to match the diameter of the Ducting you have in place though.If you have any additional questions please call me on 0208 463 9696.BenReplied by i-sells, 26-06-2021#9EngineerIs this product suitable for gas laundry appliances?
Question by Mark Goodwin, 27-06-2021Good morning Mark, and thanks for the question. The Cowled outlet grill that we supply is for air ventilation. You would need to check with the manufacturers of your laundry machine to see if it is suitable.
Kindest regards,MarcReplied by i-sells, 28-06-2021#10Shutters?Does this include shutters under the cowl that prevent back-drafting when the extractor is not in use. Are the shutters equivalent to the Kair 100mm Wall Outlet - Gravity Grille Stainless Steel Ducting Vent? Is there a bug mesh? I wonder why your website does not include a well-lit photo showing inside the cowl and/or a diagram that completes the picture that says 1000 words.
Question by James Gibbons, 31-07-2022Hi James, there is a backdraught damper behind the cowl that closes when the fan is not in use. This grill does not have or require a mesh as the damper flap does will be in closed position when the fan is not in use.
Kind regards,MarcReplied by i-sells, 01-08-2022 -
DELIVERY
Delivery: You'll receive in: Cost Min Order Free Delivery 3 to 5 Days FREE £100 Standard 2 to 4 Days £4.99 - Express Courier Next day+ £9.95 Any View Full Delivery Info
FREE Delivery for orders over £100 inc VAT.
+ Order before noon for Next Working Day Delivery for items in stock
Excludes Highlands, Islands, and Certain Postcodes.
Please Note: Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.