T-Series Darkroom Model
OverviewA range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office.
Model Range | | TX6DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TL6DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TX7DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TL7DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TX9DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TL9DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TX12DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
 | | TL12DR | | A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. | |
|
Accessories | | Ecotronic 130 Controller | | All the features of T-Series:- * Infinitely variable speed control * 'E' position for energy saving * Minimum speed adjustment. | |
|
 | | Ecotronic 400 Controller | | For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller. | |
|
 | | Ambient Response Humidity Sensor | The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On' for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Can be wired into controller "Auto" mode connections. Night time RH increment setback feature suppresses uisance tripping when the humidity level gradually rises as the temperature falls. Features & Benefits: - Ambient operating temp range +5°C to +40°C.
- Changeover relay switch.
| |
|
 | | Air Quality Sensor | | Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. | |
|
 | | Ecotronic Humidity Sensor | An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90%RH. Can be wired into controller "Auto" mode connections. Incorporates changeover switch to select low/high speed. Features & Benefits: - Ambient operating temp range 0°C to +40°C.
- BEAB Approved.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Maximum switching load 1 amp inductive.
- Pullcord override indicated by lamp.
- Setting Range: 65% - 90%RH.
| |
|
ShutterWith energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C. ElectricalSuitable for running at any angle. Quiet running, enclosed. Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.). Supply voltage: 220-240V/1/50Hz (120V/1/60 Hz).
| Unit size | 6 |
|---|
| Type | TX6DR | TL6DR | | Stock Ref. No. | W16 12 10 | W26 12 10 | | Amps @ 240V | 0.24 | 0.21 | | Extract Performance m³/h | Low | 200 | | Extract Performance m³/h | Med | 240 | | Extract Performance m³/h | High | 265 | | Watts (high) | 45 | 40 | | dB(A) (med) @ 3m | 43 | | Shutter (TX only) Instant | | Surface Controllers | T-Series Type TSC | W36 11 19 | | Surface Controllers | Ecotronic 130 | W30 01 20 | | Surface Controllers | Ecotronic 400 | W36 23 20 | | Surface Controllers | Time Switch TTC | W36 13 10 |
| Unit size | 7 |
|---|
| Type | TX7DR | TL7DR | | Stock Ref. No. | W16 22 10 | W26 22 10 | | Amps @ 240V | 0.24 | 0.21 | | Extract Performance m³/h | Low | 330 | | Extract Performance m³/h | Med | 415 | | Extract Performance m³/h | High | 530 | | Watts (high) | 46 | 41 | | dB(A) (med) @ 3m | 2 | | Shutter (TX only) | Instant | | Surface Controllers T-Series | Type TSC | W36 11 19 | | Surface Controllers T-Series | Ecotronic 130 | W30 01 20 | | Surface Controllers T-Series | Ecotronic 400 | W36 23 20 | | Surface Controllers T-Series | Time Switch TTC | W36 13 10 |
| Unit size | 9 |
|---|
| Type | TX9DR | TL9DR | | Stock Ref. No. | W16 32 10 | W26 32 10 | | Amps @ 240V | 0.42 | 0.39 | | Extract Performance m³/h | Low | 455 | | Extract Performance m³/h | Med | 630 | | Extract Performance m³/h | High | 725 | | Watts (high) | 80 | 75 | | dB(A) (med) @ 3m | 42 | | Shutter (TX only) | Instant | | Surface Controllers | T-Series Type TSC | W36 11 19 | | Surface Controllers | Ecotronic 130 | W30 01 20 | | Surface Controllers | Ecotronic 400 | W36 23 20 | | Surface Controllers | Time Switch TTC | W36 13 10 |
| Unit size | 12 |
|---|
| Type | TX12DR | TL12DR | | Stock Ref. No. | W16 42 10 | W26 42 10 | | Amps @ 240V | 0.51 | 0.48 | | Extract Performance m³/h | Low | 870 | | Extract Performance m³/h | Med | 1040 | | Extract Performance m³/h | High | 1130 | | Watts (high) | 105 | 100 | | dB(A) (med) @ 3m | 42 | | Shutter (TX only) | Instant | | Surface Controllers | T-Series Type TSC | W36 11 19 | | Surface Controllers | Ecotronic 130 | W30 01 20 | | Surface Controllers | Ecotronic 400 | W36 23 20 | | Surface Controllers | Time Switch TTC | W36 13 10 |
 Flush box Stock Ref. No. 40 01 44
|