 The VA100 range from Vent-Axia is designed for domestic bathrooms and WC's. Available as window, wall or panel mounted models. A range of fans with options of shutter, timer or humidity controlled versions.
The VA100 meets and exceeds the Building Regulation (Document F) requirements of 15 l/s for domestic bathrooms with integral WC's. Designed in a clean white finish. Suitable for ambient temperatures up to +40°C fitted with ball bearing motors. IPX4 Rated.  VA100L - Bathroom extract fan. BEAB Approved. Stock Ref. No. 25 11 10
VA100LT (Timer) - Bathroom and WC fan with adjustable electronic overrun timer and neon light. BEAB Approved. Stock Ref. No. 25 12 10 VA100X (Shutter) - Bathroom fan with thermo-electric shutter, pullcord and neon light. BEAB Approved. Stock Ref. No. 25 13 10 VA100XT (Timer/Shutter) - Bathroom fan with adjustable electronic overrun timer, thermoelectric shutter and neon light. BEAB Approved. Stock Ref. No. 25 14 10 VA100LH (Humidity) - Bathroom fan with presettable integral auto humidity control, neon running light and pullcord. BEAB Approved. Stock Ref. No. 25 16 10 VA100XH (Shutter/Humidity) - Bathroom fan with presettable integral auto humidity control, thermo-electric shutter, neon running light and pullcord. BEAB Approved. Stock Ref. No. 25 17 10 VA100HT (Shutter/Humidity/Timer) - Bathroom fan with presettable integral auto humidity control and adjustable electronic overrun timer, thermo-electric shutter and neon light. Stock Ref. No. 25 15 10 VA100WCX (Shutter) - WC extract fan with thermo-electric shutter, pullcord and neon light. BEAB Approved. Stock Ref. No. 25 18 10 VA100WCXT (Shutter/Timer) - With adjustable electronic overrun timer, thermoelectric shutter and neon light. BEAB Approved. Stock Ref. No. 25 19 10 
| Type | Stock Ref. No. Panel Model | Window Kit | White Grille Wall Kit | Brown Grille Wall Kit |
|---|
| VA100L | 25 11 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100LT | 25 12 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100X | 25 13 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100XT | 25 14 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100LH | 25 16 10C | 25 41 01 | 25 41 02 | 25 41 00 | | VA100XH | 25 17 10C | 25 41 01 | 25 41 02 | 25 41 00 | | VA100XHT | 25 15 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100WCX | 25 18 10 | 25 41 01 | 25 41 02 | 25 41 00 | | VA100WCXT | 25 19 10 | 25 41 01 | 25 41 02 | 25 41 00 |
| Type | Stock Ref. No. | Extract Performance (panel model) | Watts | dB(A) @ 3m | Shutter |
|---|
| m³/h | l/s |
|---|
| VA100L | 25 11 10 | 90 | 25 | 15 | 32 | | | VA100LT | 25 12 10 | 90 | 25 | 15 | 32 | | | VA100X | 25 13 10 | 90 | 25 | 20 | 32 | Thermo | | VA100XT | 25 14 10 | 90 | 25 | 21 | 32 | Thermo | | VA100LH | 25 16 10C | 90 | 25 | 16 | 32 | | | VA100XH | 25 17 10 | 90 | 25 | 21 | 32 | Thermo | | VA100XHT | 25 15 10 | 90 | 25 | 21 | 32 | Thermo | | VA100WCX | 25 18 10 | 70 | 19 | 18 | 30 | Thermo | | VA100WCXT | 25 19 10 | 70 | 19 | 19 | 30 | Thermo |
 VA100 models are fitted with an electronic timer which provides the necessary 15 minute overrun time to comply with Building Regulation (Document F) requirements for internal WC ventilation. Adjustable from 3-20 minutes.
To meet IEE Regulations, timer models should be isolated using a 3 pole isolator. Stock Ref. No. 56 35 18  Panel Model

| Air Replacement Grille Set | | Ivory Stock Ref. No. 56 14 01 Brown Stock Ref. No. 56 14 00
|  | | Quick fix 100mm Wall Grille | | Ivory Stock Ref. No. 56 35 21 Brown Stock Ref. No. 56 35 41
|  | | Quick fix 100mm Airflow Shutter | | Ivory Stock Ref. No. 56 35 22 Brown Stock Ref. No. 56 35 42
|  |

| | A | B | C | D | E | F | G |
|---|
| mm | 155 | 44 | 56 | 98 | 32 | 89 | 200 | | Transformer | 148 | 87 | 19 | 49 | | | | | Weight 0.55 kg | | | | | | | |
Panel Model
 Fixing hole diameter 105mmØ Window Model
 Fixing hole diameter 105mmØ Wall Model
 Fixing hole diameter 117mmØ when wall kit is used. Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used.  Supply and install a VA100 mains axial fan suitable for mounting in panels, walls or windows, with thermally operated backdraught shutter (X, XT, XH and XHT models only), removable grille and fan running light as supplied by:
Vent-Axia Ltd Fleming Way Crawley West Sussex RH10 9YX Telephone: 01293 526062. The fan performance should meet the Building Regulation (Document F) requirements of 15 litres a second for bathrooms and 6 l/s for toilets,(15 minute timer overrun model for internal WC's). The fan should have a ball bearing motor for installation at any angle. The motor should be insulated to Class B. The fan should be BEAB approved. Operation
| | VA100L | - via light switch | | VA100X | - via light switch
| | VA100LT | - via light switch with timer overrun facility
| | VA100XT | - via light switch with timer overrun facility
| | VA100LH | - via light switch with integral humidity sensor and pullcord fan override
| | VA100XH | - via light switch with integral humidity sensor and pullcord fan override
| | VA100HT | - via integral humidity sensor/timer overrun facility.
|
| | | 115mm hole is drilled with a core cutter when using a wall fitting kit. | Then the telescopic wall liner is fitted |
 |