Standard:
Factory Set Options
Supply and install a Vectaire WHHR Mini DC energy efficientMVHR as manufactured by Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Bucks, HP12 3RH. The unit is to give low level, continuous ventilation to a kitchen and one other wet room. The unit should be for loft or void installation and recover up to 83% of heat from extracted air separating the airflows using a counter flow heat exchanger. The unit should incorporate a low energy EC motor with sealed for life bearings for low noise levels and low energy consumption, and have as standard: variable adjustment; boost setting with integral overrun timer; optional delay-on timer; integral frost-stat; and a water level sensor. It should also have the facility for: change of ductwork handing; purge boost; BMS connections; integral proportional dynamic humidistat; and an automatic summer bypass. The unit should be capable of being fitted to 125mm dia ducting without the need for adaptors, have EPS lining for low noise levels and low heat loss. The unit should comply with Part L1 2013 and Part F 2013 of Building Regulations, be EU RoHS Directive Compliant, conform to the requirements of EC Council directives relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/CE (LVD), 2004/108/CE (EMC), EN 60335-2-80, be CE marked and SAP Q Eligible
Heat Recovery Efficiency (Up to - %) | 83 |
CE Marked | Yes |
Product Category | Heat Recovery Unit |
Round System (mm) | 125 |
Product Type | Heat Recovery - Whole House |
Product Group | Ventilation Fan |
Product Variety | Right hand drain |
Length (mm) | 400 |
Width (mm) | 400 |
Height (mm) | 220 |
Spigot size (mm) | 125 |
Voltage (V) | 220 - 240 |
Power Min (Watts) | 15 |
Power Max (Watts) | 80 |
Decibel Rating (dB) - Low | 18 |
Decibel Rating (dB) - Max | 37 |
Temp Max (°C) | 60 |
Economy Delivery | Not Eligible |
Manufacturer Product Code | WHHRMINI-RB |
Airflow Performance (l/s) - Low | 12 |
Airflow Performance (l/s) - Med | 28 |
Airflow Performance (l/s) - High | 34 |
Airflow Performance (m³/h) - Low | 43.2 |
Airflow Performance (m³/h) - Med | 100.80 |
Airflow Performance (m³/h) - High | 133.20 |
SAP Appendix Q applicable | yes |
Warranty (Years) | 2 |
Quick Search: | QS45667 |
Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
Display says clean filter does this refer to unit in roof or individual filters in room ceiling
Good morning. It will refer to the filters in the unit itself. There should be 2 of them. They should be cleaned or changed every 12 months.