DOMUS THERMAL EASIPIPE RIGID DUCT 125MM INSULATION HORIZONTAL T PIECE GREY Clam shell style insulation designed to insulate 125mm round domestic ventilation ducting passing through cold areas. Plastic ducting itself not included. Exceeds the requirements of the current Building Regulations. Genuine Domus Ventilation product supplied by i-sells ...
Clam shell style insulation designed to insulate 125mm round domestic ventilation ducting passing through cold areas.
Plastic ducting itself not included.
Exceeds the requirements of the current Building Regulations.
Genuine Domus Ventilation product supplied by i-sells - Shop with confidence
Domus Thermal is a unique (patent pending) duct insulation system, designed specifically to comply with 2010 Building Regulations and to radically improve the thermal insulation of ventilation ducting in domestic properties.
Approved Document F of Building Regulations 2010 states that all ducting installed in domestic properties, which passes through unheated areas or loft spaces, should be insulated with the equivalent of at least 25mm of a material having a thermal conductivity of ≤0.04 W/(m.K) to reduce the possibility of condensation forming.
The loss of heat through poorly insulated duct systems means that modern homes are at risk of losing a valuable source of energy; for example, when using warm exhaust air to heat fresh incoming air through an MVHR system or exhaust air heat pump.
Domus Thermal exceeds these regulations, having a thermal conductivity of ≤0.03 W/(m.K), thus providing better insulation and peace of mind that the system will be compliant and save energy. This greatly improved thermal conductivity allows the wall thickness to be reduced to just 20mm in most profiles.
The only engineered duct insulation solution which complies with 2010 Building Regulations. The thermal performance of the range, in relation to 2010 Building Regulations, has been independently ratified by one of the UK’s leading thermodynamics experts.
≤0.04 W/(m.K) thermal conductivity at 25mm insulation thickness Minimum thermal resistance or R-value = 0.025/0.04 = 0.625 K/W Domus Thermal provides: ≤0.03 W/(m.K) thermal conductivity at 20mm insulation thickness Minimum thermal resistance or R-value = 0.020/0.03 = 0.666 K/W The increased thermal resistance of Domus Thermal therefore exceeds current Building Regulations.
Domus Thermal products are recyclable and when installed in accordance with Polypipe Ventilation’s installation guidelines, Domus Thermal offers a life expectancy greater than or equal to that of the Domus duct system.
Domus Thermal has an excellent Ozone Depletion Potential (ODP) of 0 and a Global Warming Potential (GWP) of <5.
Current available, compliant, solutions are more labour intensive and require higher skill levels to install. Domus Thermal’s simple interlock feature means that the system is quicker and easier to install, as joints require no taping or sealing. This revolutionary method can significantly reduce installation costs.
Domus Thermal is available in a range of profiles and fittings to insulate the Domus EasiPipe (round) and Supertube (rectangular) duct systems. To support the system, PVC coated, perforated steel banding is also available for surface mounting or suspending the insulated system. The use of this soft-edged fixing system is strongly recommended to ensure that the insulated duct is held securely without damage.
The interlocking feature and regular external profile provides homeowners with a neat, professional and continuous appearance.
Domus Thermal is manufactured from flame retardant (EN 13163 class E) Silver EPS (expanded polystyrene), which provides its enhanced thermal insulation properties and enables the system to exceed the requirements of the current Building Regulations.
The Silver EPS used to manufacture Domus Thermal provides a significantly improved thermal conductivity value due to the addition of specifically engineered carbon particles. This also gives Domus Thermal its distinctive silver colour.
Round System (mm) | 125 |
Product Group | Plastic Ducting |
Colour | Grey |
Barcode | 5053062001992 |
Barcode - Type | EAN |
Manufacturer Product Code | TS592 |
Quick Search: | QS46576 |
Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
Customers who bought this product also purchased |
Ducting System | Actual dimensions (mm) | Space requirements (mm) | Airflow mm² |
For 4" (100mm) extractor fans or for low power cooker hoods up to 250m³/hour | |||
---|---|---|---|
System 100 - Round | 100 | 106 | 7,854 |
System 100 - Rectangular | 110 x 54 | 116 x 60 | 5,940 |
For medium extraction rates or if available depth is limited up to 500m³/hour | |||
System 125 - Round | 125 | 131 | 12,272 |
System 125 - Rectangular | 150 x 70 | 156 x 76 | 10,500 |
For 6" (150mm) extractor fans or for high power cooker hoods up to 500m³/hour & above | |||
Megaduct 220 - Rectangular | 220 x 90 | 227 x 97 | 17,968 |
System 204 - Rectangular | 204 x 60 | 210 x 66 | 12,240 |
System 150 - Round | 150 | 156 | 17,671 |
System 150 - Rectangular | 180 x 90 | 186 x 96 | 16,200 |
For a shallow space, such as ceiling voids or under floor, where high extraction rates are not needed: | |||
System 300 - Rectangular | 308 x 29 | 314 x 35 | 8,932 |
System 225 - Rectangular | 234 x 29 | 240 x 35 | 6,786 |
System 100 Round/Rectangle | System 125 Round/Rectangle | System 150 Round/Rectangle | System 204 | System 225 |
System 220 | System 300 | |||
Actual Dimensions (mm) Space Requirements (mm) |