Vent Axia ACM125T In Line Fan 125mm Three Speed With Timer
-
DETAILS
VENT AXIA ACM125T (17105020)
Mixed Flow Inline Duct Fan with timer for 125mm ducting.
In-Line Mixed Flow fans offer two and half times the pressure of conventional axial fans, are dimensionally more compact making them ideal for many ducted applications. The impeller blade design with guide vanes provides optimum pressure characteristics and simple connectivity and quieter more efficient running provides the complete solution.
The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions and can be mounted to meet its optimum performance.
Features & Benefits
- Market-leading performance
- Incredibly quiet operation
- Designed and manufactured in UK
- Three-speed selectable motor
- Timer version
- Please note Vent Axia ACM Timer Models are not compatible with speed controllers
- Removable motor core assembly
- Rotating motor chassis assembly
- Compatible with the extensive i-sells.co.uk Ducting Range (Ducting Not Included)
- IP44 rated
- Aesthetically pleasing construction with wipe-clean polymer casing
Range Product Specification
Motor
All motors are fitted with Standard Thermal Overload Protection. (S.T.O.P.). Designed for ambient temperatures up to +50°C.
Size 100 and 125 with shaded pole motors. Size 150, 200, 250 and 315 with capacitor start and run motors. All sizes are Class II appliances except ACM250 and ACM315 which is Class I Supply voltage 220-240V/1/50Hz.
Typical Range Specifications
Supply and install the ACM range of commercial In-line fans as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: 01293 526062.
The fan should be of the mixed flow design specifically for use with rigid and flexible ducting with energy efficiency and low sound levels in mind. The fan shall be fitted within the ducted system and isolated from the building structure by means of Anti- Vibration mountings.
The fans should be dimensionally compact saving weight and installation costs. The casing should be manufactured from galvanised sheet steel and manufacture is controlled to BS EN ISO 9001.
The fan motor should be removable by means of 2 Clip Bands for ease of maintenance.
Motors should have ball bearings greased for life to allow the fan to be installed at any angle and should have Class B insulation to allow the fan to work satisfactorily in ambient air temperatures from -5°C to +50°C and should be fitted with Standard Thermal Overload Protection (S.T.O.P.).
-
FEATURES
Features
- 125mm Timer Version
- Quietest on the market
- Designed and manufactured in UK
- Rotating motor chassis assembly
- Compatible with the extensive i-sells.co.uk Ducting Range (Ducting Not Included)
-
TECHNICAL
Technical Specifications
Timer Yes Product Category In-Line Fans Round System (mm) 125 Product Type Mixed Flow In-Line Fan Product Group Ventilation Fan Length (mm) 230 Width (mm) 210 Height (mm) 360 Spigot size (mm) 122 IP Rating IP44 Power Min (Watts) 25 Power Max (Watts) 30 Decibel Rating (dB) - Low 20 Decibel Rating (dB) - Max 24 Colour White Weight (Kg) 2.078 Packaged Weight (Kg) 2.078 Packaged Length (mm) 230 Packaged Width (mm) 210 Packaged Height (mm) 360 Manufacturer Product Code 17105020 Vent Axia (similar) ACM125T Airflow Performance (l/s) - Low 65 Airflow Performance (l/s) - High 91 Airflow Performance (m³/h) - Low 234 Airflow Performance (m³/h) - High 327 Warranty (Years) 2 Quick Search: QS9999 -
REVIEWS
-
Q & A
Product Questions
Questions and Answers, do you need more information about this product?
Ask a QuestionYour question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
#1acm fan 125TCan this fan be used remote motor and kupperbush chimney hood which has variable speed
Question by B.KArim, 20-08-2015Hello Mr Karim
Thank you for your question.
You can add an in-line fan to your cooker hood if your cooker hood is not powerful enough. but it would depend on how long your duct run is also how many bends you have and what size ducting is existing as most cooker hoods are either 150mm and sometimes reduce to 125mm . If you can advise me of this ,I then can confirm if the fan would be suitable
Replied by i-sells, 21-08-2015#2Extractor InletsCan I have more than one inlet point if I use 'Tee' duct piece and use one fan? (i.e one point over shower and one point over bath?)
Question by Derek Gage, 25-10-2015Hello Derek
Thank you for your question. You can have two extract points depending on how long your duct run is. We normally say 8mtrs straight or 6mtrs with two bends.
Replied by i-sells, 27-10-2015#3humidistat and timerIs it possible to control the above fan with both humidistat and timer. ie PIR detects person in room fan runs timed and stops (toilet use). If humidity rises or is high(shower use) fan continues to run until humidity cleared.
Question by Brian Binns, 27-01-2016Hello Brian,
Unfortunately the ACM125T model cannot be used with any controller. The ACM125 model (Without timer) can be used with external controllers.
Please see the the catalogue page for further information on the control options. Did you have a particular PIR sensor and Humidistat controller in mind?
Kind regards,
MichaelReplied by i-sells, 28-01-2016#43x Ducts?1. Can the ACM125T be ducted to three inlet positions? Each in a different room. They would have duct lengths of 1m, 1m and 3m. Each duct would need to have a non-return flap/valve. 2. Can the ACM125T be connected to a 110mm pipe leading to the exterior and still achieve 327m3 airflow performance? With a reducer piece?
Question by Jon, 06-08-2019Hi Jon
The ACM is suitable for installations involving 6m of ducting so the lengths you have indicated are ok.We are not sure about the non return valves as if the fan is running all of them will be open, not running all closed?The flow rate you mention is the highest speed capable for this machine and therefore, requires the least resistance, it is not possible to force air that requires 125m ducting through a 110mm space in the same way it is not possible to force 2 litres of water into a 1 litre bottle.Replied by i-sells, 07-08-2019 -
DELIVERY
Delivery: You'll receive in: Cost Min Order Free Delivery 3 to 5 Days FREE £100 Standard 2 to 4 Days £4.99 - Express Courier Next day+ £9.95 Any View Full Delivery Info
FREE Delivery for orders over £100 inc VAT.
+ Order before noon for Next Working Day Delivery for items in stock
Excludes Highlands, Islands, and Certain Postcodes.
Please Note: Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.