Vent Axia Lo-Carbon Sentinel Multivent H MEV Unit (445655)
-
DETAILS
VENT AXIA LO-CARBON SENTINEL MULTIVENT H
Sentinel Multivent continuous mechanical extract ventilation, MEV is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The units can be installed at any angle. Where the ambient air has a high humidity content condensate drains are provided.
Features and Benefits:
Sentinel Multivent has been designed to meet the exacting demands of developers, installers and users offering advanced control options and easier installation and commissioning.
- Demand Control - enables precise ventilation rate, is set in 1% increments based on property size
- The integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand
- Manual and automatic control options
- Integral adjustable overrun timer and delay on timer
- Plug-n-Play automatic sensor detection
- Switched live and SELV connections
- Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture
- Optional Wireless Control – up to 4 controllers on any one system
- Energy-efficient EC/DC motors - 1/3 less energy lost to heat than a conventional AC motor
- Low Specific Fan Power (SFP) making it one of the most efficient products on the market
- £15 to run per annum depending on the energy provider
Legislation:
- Meets Building Regulations Approved Document F (System 3)
- Recognised in SAP PCDB up to kitchen + 6 wet rooms
- Meets carbon footprint reduction targets
- Lowest SFP figures of any demand control MEV system
The need for a healthier environment:
Removal of pollutants such as moisture, carbon dioxide and external fumes are all important factors in maintaining indoor air quality, helping to create a healthier living environment.
- The integral humidity sensor (Sentinel Multivent H) increases fan speed in proportion to relative humidity levels, saving energy and reducing noise
- The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room
- Nighttime relative humidity increment setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature
- Acoustically lined - low noise levels only 18.1 dB(A) @ 3m
SAP PCDB:
In order to make the right choice, developers and contractors should refer to Building Regulations ADL1a, SAP 2012 and SAP PCDB. SAP PCDB was launched in June 2006 to reward innovative ventilation manufacturers by testing and listing energy-efficient products that assist in helping developers meet their Target Emission Rates (TER). SAP is the underpinning methodology behind the Energy Performance Certificates and is used to demonstrate compliance with Building Regulations for Dwellings - Approved Document L (England and Wales), Section 6 (Scotland) and Approved Document F (Northern Ireland). SAP PCDB specifically relates to whole-house ventilation systems and lists a number of Vent-Axia Mechanical Ventilation solutions which offer an improved SAP rating over and above the default for these product types.
Your Carbon Footprint:
The Carbon Footprint is a measure of the amount of carbon dioxide (CO2) emitted through the burning of fossil fuels. From a residential and commercial building perspective, it is the amount of carbon generated when you consume a kilowatt of electricity. Reducing a building’s carbon footprint will ultimately reduce electricity bills and save money for every individual household or business. It will also help meet the UK target for the reduction of emissions, as well as allowing you to help the environment.
Controllers and Sensors:
Sentinel Multivent can be used with a wide range of Vent-Axia controllers and sensors. Ranging from integral humidistats, through wireless controllers to wired remote sensors.
Sound Data:
Induct Sound Power Levels dB dB(A)
@ 3mSpeed (pwm) 63 125 250 500 1K 2K 4K 8K 10% Breakout 43.6 37 36.9 30.6 26.2 22.8 23.6 30.8 18.1 Extract 43.8 39.9 36.1 30.4 24.6 21.8 22 30.3 17.8 28% Breakout 44 44.4 43.3 39 31.1 26.1 24.3 30.1 22 Extract 42.2 40.1 42.2 40.5 32 23.3 23.4 30.5 22 46% Breakout 45 42.8 46.7 44.1 38.8 35.6 26.7 30.6 25.8 Extract 40.8 42.5 46.4 44.4 41 31.1 25.3 30.3 26 82% Breakout 46.3 48.3 50 52.1 48.4 47.7 37.8 32.4 33.7 Extract 46.7 49.6 48.9 54.3 51.8 42.7 38.1 34.2 36.1 -
FEATURES
Features
- Continuous running mechanical extract system with integral humidity sensor
- Designed for the simultaneous ventilation of separate ares in the home or as a multipoint extraction system for a wide range of commercial applications.
- The integral humidity sensor increases fan speed in proportion to relative humidity levels, saving energy and reducing noise.
- Please note the latest Vent Axia model will be supplied with a full manufacturer's warranty
- Sentinel Multivent has been designed to meet the exacting demands of developers, installers and users offering advanced control options and easier installation and commissioning.
-
TECHNICAL
Technical Specifications
Product Category MEV Units Round System (mm) 125 Product Type MEV Product Group Ventilation Fan Product Variety Humidistat Length (mm) 360 Width (mm) 310 Height (mm) 260 Power Max (Watts) 45 Decibel Rating (dB) - Max 38 Economy Delivery Not Eligible Next Day Delivery Temporarily not eligible for next day delivery Manufacturer Product Code 445655B Vent Axia (similar) 445655 Warranty (Years) 2 Quick Search: QS10018 -
REVIEWS
-
Q & A
Product Questions
Questions and Answers, do you need more information about this product?
Ask a QuestionYour question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
#1Condensate Drain Reqd?Does this item need a condensate drain? I can't see any mention of this in the fitting & wiring instructions
Question by John Garrick, 06-07-2022Hello John
Thank you for your question. Having spoken to Vent Axia's technical department they have confirmed there is no need for a condensation drain for this unit. If you require any further assistance please do not hesitate to contact meKind RegardsAnitaReplied by i-sells, 06-07-2022 -
DELIVERY
Delivery: You'll receive in: Cost Min Order Free Delivery 3 to 5 Days FREE £100 Standard 2 to 4 Days £4.99 - Express Courier Next day+ £9.95 Any View Full Delivery Info
FREE Delivery for orders over £100 inc VAT.
+ Order before noon for Next Working Day Delivery for items in stock
Excludes Highlands, Islands, and Certain Postcodes.
Please Note: Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.