<< Close Menu
Close Menu >>
Top » Ventilation Fans » Ventilation - Positive Pressure

Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch

Model: NUADRI-ECO-HEAT-HC-BUN-ECO-4S
Search: QS52108
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
  • Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire and 4 way switch
Availability: In Stock
 £650.00 Inc VAT
  • DETAILS

    Nuaire Drimaster Eco Heat - Condensation Solving Loft Unit

    Included in bundle:
    x1 NUADRI-ECO-HEAT-HC (Drimaster Eco Heat Positive Input Ventilation Unit With Integral 400W Heater By Nuaire)
    x1 DRI-ECO-4S (Nuaire Drimaster DRI-ECO-4S Eco 4 Way Heater and Boost Control Switch)

    How to install your Drimaster unit

    • 1. To install the diffuser, cut out a section of the ceiling in the central position of your landing hallway. If possible, at least 1m away from a smoke alarm or CO2 monitor.
    • 2. In the loft cavity, mark the centre point between two joists, and drill a hole in the centre point.
    • 3. Using the diffuser template provided, line up the centre point, and mark out the section to be cut out of the ceiling.
    • 4. Cut out the section of ceiling ready for the diffuser, then fit the diffuser into the hole, and secure with the screws and plasterboard plugs provided.
    • 5. Once the diffuser is secured, fit the ducting over the heater and over the screws, then attach the supplied cable tie below the screws to secure the duct to the heater.
    • 6. Connect the data cable to the diffuser interface panel, then the heater to the diffuser.
    • 7. Attach the ducting to the fan, and secure using a cable tie.
    • 8. Fix a screw to a convinient joist near the diffuser. If possible, suspending the unit approx 2/3 of the loft height to capitalise on solar gain, making sure the duct is not overstreteched.
    • 9. Ensure that the filters are fitted securely.
    • 10. When the unit is in position, connect the data cable from the heater to the unit, then the heater mains cable back to the unit.
    • 11. Ensure there is a minimum of 50mm between the heat power and data cable.
    • 12. Before connectiong the drimaster eco to the phase connection unit, check that supply voltage is correct. Isolate at the mains before connecting the drimaster to the fuse connection unit. Then re-instate the power supply.

    At i-sells we are a ';Tier 1'; Nuaire distributor. All Nuaire Products supplied by i-sells are genuine Nuaire stock and come with a full Nuaire warranty effective from the date of delivery. Any questions? Please contact us!

     

    Nuaire Drimaster Hung Loft Units

    The unique DRI-ECO-HEAT-HC incorporates all of the functions of our DRI-ECO-LINK-HC unit but with the benefit of an integral heating element, located between the flexible duct and ceiling diffuser.

    This heating component will temper the air which is distributed through the property via the ceiling diffuser, thus ensuring a comfortable living environment. This pioneering design sees the low watt heater (400w) react efficiently and effectively, guaranteeing an economically friendly product.

    A temperature sensor on the outside of the unit monitors and controls the heater output to maintain the set point. The set point ranges from 5° to 15° and can be adjusted from the ceiling diffuser. If the temperature at the heater outlet is above the set point, the heater will not activate. 

     

    Please note, it is not possible to retro-fit a heater to other Drimaster Eco models.

    The DRIMASTER-ECO range provides whole home ventilation using the Positive Input Ventilation principle, which introduces fresh filtered air into the dwelling at a continuous rate, encouraging movement of air from inside to outside.


    NUAIRE INVENTED PIV OVER 40 YEARS AGO

    It has become the UK';s most popular alternative method of low energy, cost-effective ventilation!

    Invented by Nuaire and installed in thousands of dwellings each year, PIV can be a more cost-effective and simple to install ventilation solution, whilst still meeting building regulations.

    CREATES A HEALTHY LIVING ENVIRONMENT


    MOISTURE AND CONDENSATION ARE DRIVEN OUT
    The filtered air gently pressurises the home from inside out, forcing out the stale air.

    NO NEED TO OPEN WINDOWS TO VENTILATE
    Clean, fresh air is continuously drawn in through the lofts natural leakage points, passed through the filters and fed into the property via a central hallway diffuser.

    Nuaire Drimaster PIV

    INSTALLATION INSTRUCTIONS

    Installation Instructions Nuaire Drimaster

    Always get a qualified electrician for fitting the unit!

    The unit is supplied with a pre-wired power supply. This power supply unit has a metal bracket incorporating fixing holes, which should be used to fit the power supply to a suitable surface, e.g. a wooden joist.

    (Please note, brackets to mount the Drimaster to wooden loft beams are not included.)  

    The fan unit is also supplied with a fused spur. The 3 core mains cable from the power supply should be connected to a fixed wiring installation, via the isolator, via the spur, in accordance with current IEE wiring regulations.

    7 YEAR WARRANTY!

    7 Year Warrany Nuaire Drimaster ECO Nuaire Drimaster Made In UK

     

    OPTIONAL CONTROLLERS & SENSORS - FOR A SMARTER HOME

    Humidity Sensor 4 Way Swtich CO2 Sensor Remote Monitoring
    DRI-ECO-RH
    Nuaire’s latest Relative Humidity sensor which reads the humidity levels in the home and feeds back to the Drimaster unit, controlling it’s running speed in order to maintain optimum comfort.
    DRI-ECO-4S
    This remote 4 button switch controls the running functions of both the Drimaster unit itself as well as the integral heater. By splitting the control options the occupier is presented with the ability to choose the function which best suits their home.
    DRI-ECO-CO2
    A Carbon Dioxide CO2 sensor which must be wired directly in to the mains power supply. This ancillary will provide complete confidence in the property';s air quality by alerting the home owner if dangerous levels of CO2 arise.
    DRI-ECO-RM
    The remote monitoring device will allow readings to be taken from outside the property to determine how long the unit has been running and the operating speed of the unit. This will benefit the social housing provider when checks are carried out.
    View Product View Product View Product View Product

     

    The Drimaster RF system can simultaneously accommodate one DRI-ECO-RH, one DRI-ECO-CO2 and one switch type, either DRI-ECO-2S pr DRI-ECO-4S.

    Multiple devices of the same type are not supported.

     

  • FEATURES

    Features

    • Heater version and 4 Way Switch Bundle - Supplies tempered & filtered air to the property
    • For homes with lofts - Whole House Condensation Control
    • Supplied with all ancillaries required for a suspension installation (Joist mounting kit sold seperately (Part: NUA771393)
    • Integral 400w Heater and Modern Circular Diffuser
    • Warranty: Complete with a FULL 7 Year Nuaire Warranty
  • TECHNICAL

    Technical Specifications

    Maximum Area / Property Size (m2) 200
    Product Category Positive Pressure Units
    Product Type Loft PIV Unit
    Product Group Ventilation Fan
    Product Variety Heater + Switch
    Length (mm) 680
    Width (mm) 338
    Height (mm) 341
    Voltage (V) 230
    Power Min (Watts) 1.6
    Power Max (Watts) 400
    Weight (Kg) 6.5
    Packaged Weight (Kg) 10
    Packaged Length (mm) 820
    Packaged Width (mm) 355
    Packaged Height (mm) 365
    Manufacturer Product Code DRI-ECO-HEAT-HC
    Airflow Performance (l/s) - Low 10
    Airflow Performance (l/s) - High 60
    Airflow Performance (m³/h) - High 216
    Maximum suggested long duct run (Mtr) 2
    Warranty (Years) 7
    Quick Search: QS52108
  • REVIEWS
  • Q & A

    Product Questions

    Questions and Answers, do you need more information about this product?

    Ask a Question

    Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.

  • DELIVERY
    Delivery: You'll receive in: Cost Min Order
    Free Delivery 3 to 5 Days FREE £100
    Standard 2 to 4 Days £4.99 -
    Express Courier Next day+ £9.95 Any

    View Full Delivery Info

    FREE Delivery for orders over £100 inc VAT.

    + Order before noon for Next Working Day Delivery for items in stock

    Excludes Highlands, Islands, and Certain Postcodes.

    Please Note:
    Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.

View Product on Full Website

You may also like

  1. List Price: £533.28
    Only: £439.99
  2. List Price: £531.07
    Only: £600.89
  3. List Price: £389.40
    Only: £374.99
  4. List Price: £617.76
    Only: £604.99
  5. List Price: £389.40
    Only: £317.99

View similar products in category:
Ventilation - Positive Pressure

Previous / Next Product