Tecsonic Duct - 100mm X 10M - Acoustic Flexible Duct With Interliner
-
DETAILS
TECSONIC DUCT - 100MMX10M - ACOUSTIC WITH INTERLINER
Tecsonic 400 is a high quality fully flexible acoustic ducting. It is ideal for use in low and medium pressure ventilation and air conditioning systems where attenuation of duct borne noise is required.
- Flexible Ducting
- Fire-resistant - Tested to and complies with BS476.
- Certified acoustic performance - independently tested.
- “S” type includes acoustically transparent interliner
- Suitable for medium and low-pressure applications.
- Individually cartoned 10-metre lengths.
- Complies with HVCA specification DW144.
Construction:
Tecsonic 400S is constructed in a similar manner to Tecsonic 400 but with the addition of an acoustically transparent interliner between the inner core and fibreglass layers. This interliner allows for good acoustical performance yet shields the airstream from the fibreglass and prevents the possibility of fibre migration into the airstream. This feature makes Tecsonic 400S especially suitable for specialist applications e.g. Food preparation, clean rooms etc. Like Tecsonic 400 this construction still provides a highly flexible duct in which bends of 1/2 D radius can be produced.
Specification:
Acoustic flexible ducting for joints or connections shall be TECSONIC 400S. It shall be manufactured with an aluminium/polyester inner core continuously perforated and wrapped with an acoustically transparent interliner. The interliner shall be covered by an overlapped fibreglass blanket with an outer jacket constructed from a reinforced aluminium fabric. The duct shall meet the time requirements of BS476 parts 6 & 7.
Packaging:
Tecsonic 400S is supplied, as standard, in 10-metre lengths. Each length is individually cartoned and labelled. Storage space required is kept to a minimum with a 10-metre length being compressed to 1150mm.
Technical Data:
- Diameter Range: 100mm to 500mm
- Temperature Range: From -30ºC to +120ºC
- Air Velocity: 15 m/s maximum
- Working Pressure: 1000 Pa maximum
- Fibreglass: 25mm thick. 16Kg/m3 density
- Outer Jacket: Scuff-resistant reinforced aluminium laminate fabric
- Colour: Metallic silver
- Standard length: 10 metres
Installation:
Fully extend ducting, then cut to exact length required using a sharp knife and pliers. Pull back fibreglass insulation and tape the inner core to the spigot. Then tape and clamp the outer jacket and inner core to the spigot.
-
FEATURES
Features
- High quality flexible acoustic ducting ideal for use where attenuation of duct borne noise is required.
- Fire resistant - Tested to and complies with BS476 (British standard 476 fire test)
- Suitable for medium and low pressure applications.
- Certified acoustic performance - independently tested.
- Complies with HVCA specification DW144.
-
TECHNICAL
Technical Specifications
Product Category Flexible Hoses Round System (mm) 100 Product Type Acoustic Ducting Hose Product Group Flexible Ducting Length (mm) 10000 Width (mm) 152 Height (mm) 100 Diameter (mm) 100 Colour Silver Material Fibreglass Weight (Kg) 2.9 Packaged Weight (Kg) 2.92 Packaged Length (mm) 980 Packaged Width (mm) 162 Packaged Height (mm) 140 Manufacturer Product Code 892409 Quick Search: QS7676 -
REVIEWS
-
Q & A
Product Questions
Questions and Answers, do you need more information about this product?
Ask a QuestionYour question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
#1Tecsonic TS400S compatibilityHi, Can you please tell me if the Tecsonic TS400S acoustic ducting is suitable for use with a bathroom extractor fan, where moisture and condensation is prevalent. Thanks
Question by Oliver, 16-06-2017Hello Oliver
The Techsonic range is still specified as extraction air ducting (with acoustic interliner) so would be suitable as would any insulated ducting. However, please ensure your bathroom fan is compatible for use with ducting in the first place, as a guide Axial fans should not exhaust through long duct runs.If ducting is required, centrifugal fans should be installed.Replied by i-sells, 16-06-2017#2Missing order 393243Hi, This item has not been delivered. Had a text from DX delivery but it never turned up. SPoke to DX and they do not have any record of it.
Question by EDWARD, 20-12-2019Hello Edward
Thank you for your inquiry. I have spoken to the factory and they have said it the item has been delivered. I am just waiting on a POD which I will send to you on a separate e-mail.Kind RegardsAnitaReplied by i-sells, 20-12-2019 -
DELIVERY
Delivery: You'll receive in: Cost Min Order Free Delivery 3 to 5 Days FREE £100 Standard 2 to 4 Days £4.99 - Express Courier Next day+ £9.95 Any View Full Delivery Info
FREE Delivery for orders over £100 inc VAT.
+ Order before noon for Next Working Day Delivery for items in stock
Excludes Highlands, Islands, and Certain Postcodes.
Please Note: Ducting tubes over 200mm in diameter and 3 metres in length may incur additional shipping charges.