100mm diameter / 121x60mm interchangeable spigots supplied with the unit
The unit is designed to take fresh air from outside, clean the air and discharge it into the central hallway via a system of ducts.
The dwelling's internal air discharge grille is usually installed at a high level in a central location within the hallway, although discharging the air down the length of the hallway (away from the front door) should also prove acceptable. Unit performance may be enhanced if an existing heat source can warm the discharged air, e.g. by locating the discharge grille above a radiator.
Based on the popular and low-energy Positive Input Ventilation principle which Nuaire invented in 1972, the Flatmaster range has been specifically designed to ventilate homes without lofts. The system introduces air into the home at a continuous low rate, eliminating condensation dampness and forcing our indoor pollutants such as Radon gas and carbon monoxide.
The aesthetically pleasing and compact unit is usually situated in a convenient location, such as a kitchen cupboard or hallway, and is ducted to a central location. Multi-positional spigots allow for quicker installation with only one external wall penetration.
Features & Benefits:
Maximum Area / Property Size (m2) | 150 |
Timer | No |
PIR | No |
Humidistat | No |
Pullcord | No |
Continuous Running | Yes |
SELV | No |
Integral Shuter | No |
Product Category | Positive Pressure Units |
Round System (mm) | 100 |
Flat System (mm) | 110x54 |
Product Type | No Loft PIV Unit |
Product Group | Ventilation Fan |
Product Variety | Standard |
Length (mm) | 485 |
Width (mm) | 160 |
Height (mm) | 320 |
Voltage (V) | 230 |
Phase | 1 |
Power Min (Watts) | 3.1 |
Power Max (Watts) | 9.4 |
Colour | White |
Weight (Kg) | 4.7 |
Packaged Weight (Kg) | 5 |
Packaged Length (mm) | 560 |
Packaged Width (mm) | 420 |
Packaged Height (mm) | 260 |
Pallet quantity | 20 |
Economy Delivery | Not Eligible |
Barcode | 5056043000311 |
Barcode - Type | EAN |
Manufacturer Product Code | FLATMASTER |
Airflow Performance (l/s) - Low | 12.5 |
Airflow Performance (l/s) - Med | 18.5 |
Airflow Performance (l/s) - High | 21.8 |
Airflow Performance (m³/h) - Low | 45 |
Airflow Performance (m³/h) - Med | 66.6 |
Airflow Performance (m³/h) - High | 78.5 |
Maximum suggested long duct run (Mtr) | 5 |
Fan Operation Modes | 3 |
Warranty (Years) | 5 |
Quick Search: | QS10003 |
Your question will be sent to a member of our team. We'll email you the answer and post it on this page. If your question is about an order you already placed, please use our Contact Form to reach the customer service team.
This is to be installed in a flat can you tell me what is the area covered please
Suitable for up to standard 2/3 bedroom flats where all rooms lead off of a central hallway where unit incoming air is discharged into.
I was wondering about noise from the system - is there any?
Hello Catherine
Thank you for your question.
There is no noise from the unit as it is whisper quite. If you have any further questions please do not hesitate to contact us.
would this unit take heat from the flat ?
Hello John
Thank you for your question. The unit is designed to take fresh air from outside, clean the air and discharge it into the central hallway via a system of ducting. If you need to extract heat then an inline fan maybe better for your application. These can be found under in-line fans on our website. Alternatively give me a call on 0208 463 9683 and I will be able to help you further
Kind Regards
Anita
Do you sell this product with the integral heater? How much is it?
Hello Julie,
We do indeed supply the unit with an integral heater. Please see our listings for the Nuaire Flatmaster 2000L and Nuaire Flatmaster 2000R for product details and pricing.
Please note that unlike the standard Flatmaster the Flatmaster 2000 model is a 'handed' unit and you need to make sure you are purchasing the correct model for your installation.
If you have any questions, please do not hesitate to give me a call on 0208 463 9670
Kind regards,
Michael
Hi, thanks for your response but I believe there is one with an integral heater where you don't have to worry about R or L? this one ODG/ref=s9_simh_gw_p60_d1_i1?pf_rd_m=A3P5ROKL5A1OLE&pf_rd_s=desktop-1&pf_rd_r=08F5K3E21TDT3GGEJBME&pf_rd_t=36701&pf_rd_p=577048787&pf_rd_i=desktop
Hello Julie,
I am afraid the link you have enclosed is not a valid link format. However, if you would like to resend the full URL I would be happy to take a look at.
However I can confirm that the Nuaire Flatmaster 2000 always is sold by the manufacturer as either a left or right handed unit, as this refers to the position of the heater element.
Because of the shape of the unit (It is slightly curved one side and has a wall-mounting on the other) it is not possible to simply flip the unit around.
The only Nuaire unit with a 'non-handed' heater is the Drimaster Heat loft-mounted positive pressure unit. Perhaps this is the unit you are referring to? The unit is aethestically different but uses a very similar principle.
Kind regards,
Michael
This is the link, it doesn't mention left or right?? http://www.amazon.co.uk/gp/product/B007NW5ODG
Hello Julie,
That seems to be a oversight on the part of the company who have listed the product for sale on Amazon (Twistfix or Bloc Electrical).
The unit is always supplied from the manufacturer in either left-handed or right-handed version. This can be confirmed by viewing the installation instructions available from the manufacturer's website (Viewable online here).
The difference is illustrated on our webshop in these two animated graphics showing airflow direction and heater positon.
Left Handed FM2000L
Right Handed FM2000R
If you can advise me further regarding your planned installation I would be happy to advise which is best for your application - These units are in our top ten best sellers so I have advised many happy customers in the past and would be happy to offer my expertise.
Kind regards,
Michael
I see the flatmaster 2000 is left or right ducted but as the option is not available on this model is it left or right ducted into the indoor space?
Hello Julian,
Unlike the Flatmaster 2000 model, you do not need to purchase a 'handed' version of the standard Flatmaster. Instead, the direction of airflow is configured at the time of installation by fitting a deflection plate which comes as standard.
Please see the downloadable PDF installation instructions, available here for full details (http://www.i-sells.co.uk/fdm_download_file.php?fileid=283)
Kind regards,
Michael
Do you have to fit the ducting un the outward part and take the ducting into the hallway or can I install it in a bedroom and just fit a vent on it to serve the bedroom area only where the condensation is at it's worse
I have a flatmaster 5+ which has a heater, the outlet plastic grill has been stuck on the output on the side of the unit and the grille has melted ? it would also seam that the fan is not allway working would the lack of air flow cause this, do you sell spare PSB boards and outlet grill. is the flatmaster the direct replacement or is it the flatmaster2000R ?
Hello Tim
Thank you for your question. The flatmaster 5+ has now been discontinued and the flatmaster left or right has taken its place. our product code for these units are QS18856 QS18857. Yes we do the grille with a round or rectangular connection. If I can help any further please do not hesitate to contact me on 0208 463 9683.
Kind Regards
Anita
Hi, Does the unit require an inlet and outlet to the outside? basicaly will it require two holes being bored in walls
Hello Philip
Thank you for your question. This unit is a positive pressure unit and not a heat recovery unit so only requires one hole . The unit is designed to take fresh air from outside, clean the air and discharge it into the central hallway via a system of ducting.
The dwelling's internal air discharge grille is usually installed at a high level in a central location within the hallway, although discharging the air down the length of the hallway (away from the front door) should also prove acceptable. Unit performance may be enhanced if an existing heat source can warm the discharged air, e.g. by locating the discharge grille above a radiator.
If I can help any further please do not hesitate to contact me on 0208 463 9683.
Kind Regards
Anita
Hi, i need to install a unit in a small one bed flat, that suffers badly from condensation. Would this unit be sufficient or should i get the version with the heater. Thanks
Hello Philip
The immediate answer to your question is yes the product will be sufficient and yes we would recommend the Heater option.
However, we would like to help you choose the correct product for your requirement and I am inclined to question why the flat suffers from condensation and is there something else that can be done to relieve the problem.
So, if you have time, could you answer the following?
Do you live there or is it rented out?
Ground, 1st - 2nd floor etc does it have a balcony?
What ventilation do you currently have in the kitchen and bathroom and how do they work (ie don't have any mechanical ventilation, fans manually operated, light activated, humidistat control etc)
Is the problem throughout the dwelling or appearing in a particular room?
Has condensation always been a problem or has it appeared recently?
Should you want clarification on why these answers may help I can be contacted on 07956 818138
Regards
Ian
I have converted part of my garage and need to provide some ventilation as per building control. Does this system need to be fitted to an outside wall?
Hello Lisa
How difficult is the product to install? Do you have any recommended installers of this product - our property is in SW20. Thanks,
Hello Carrie
Thank you for your question. We recommend that a qualified electrician installs the unit. However my colleague Ian will respond to you on a separate e-mail.
Kind Regards
Anita
on the knockout entry points on the back, how does the 100mm tube attach? thanks
Hello Derek
Hi, we have a 3 bedroom basement flat/garden flat. Our bathroom is situated in the middle of the flat, would it be ok to install the flatmaster were the old vent has been put in the bathroom? Bathroom door is usually left open. Am I also right in believing that it does not need to be heated as we live there and will not turn it off? Many thanks Debra
Hi Debra
Would this unit be suitable to bring fresh air from outside to ventilate a spare bedroom with large (former shopfront) window which doesn`t open? Would it be quiet enough?
Hello Sally
Hi, Is there a limit to the total length of ducting used with the Flatmaster?
Hi Matt
If I fitted the Flat master system in a 2 bedroom flat would it require any supplementary extract fans located in the kitchen and bathroom?
Hello Paul
Do you install this product as well ?
Hello Karthik
Dear Sir or madam Due to my particular circumstances and limited space I would like to use the Flastmaster with it positioned horizontally, i.e. sat flat on a shelf, rather than vertically as per the picture above. Is this possible? Many thanks for your assistance. John
Hello John
We have black mould appearing in a flat that previously had no issues, although major works were carried out by the local authority and new tenants moved in at the same time. This is a maisonette and the problem is present in the bedrooms. Should we install this upstairs, as this is where the problem lies and can you please recommend a local installer for SW8 - what is the average cost to install? Many thanks
Hello Indira
I have a problem with bad condensation/mould in my 2 bed bungalow. Can this unit be installed in a cupboard or does it need to be installed on an outside wall ?
Hello Annie
I already have a Flatmaster 2000L but it has just broken. I am looking to buy a replacement, will I be able to set this up to a left handed unit easily myself ?
Hello Chris
Hello. Does this need to be installed high up? I am hoping to install it 1m from ground level, with the ducting then dispersing the air upwards from a vent Would this work? I hope you can help Thank you Terry
Hi Terry
Is the filter in the unit HEPA? If not, can these be purchased separately for it? Many thanks
Hi Elizabeth
|
Customers who bought this product also purchased |