Loft mounted positive input fan draws fresh air from the atmosphere, filters it and pushes into the dwelling via a ceiling-mounted diffuser, includes an integral heater. All stale air in the property is forced out through the natural forms of ventilation, such as window mounted trickle vents.
Product Specification
It is simply installed, out of sight in the loft space, with a purpose-designed diffuser normally located over the stairwell of a conventional two story house.
PoziDry is set to the appropriate speed at installation based on the size of the dwelling, providing positive pressure input ventilation.
Background ventilation openings provide exhaust points.
The unit includes a filter with up to 5 years of maintenance free to reduce the number of call-outs needed throughout its life span.
The unit includes a time elapse meter to enable precise running information.
With a selection of 2 of 6 speeds available up to 50l/s, the unit is suitable for houses up to 150m3.
The electronically controlled DC motor is manufactured with long-life ball bearings and is fitted with Standard Thermal Overload Protection (S.T.O.P.). Suitable for ambient operating temperatures of -25˚C to +40˚C.
Performance
The robust construction of the PoziDry features a specially developed LoWatt DC fan/motor arrangement quietly delivers incredibly low running costs. The special insulation mount provided ensures PoziDry is user friendly and quiet in operation.
Can be used for air replacement in conjunction with an extract fan.
Speed | 1 | 2 | 3 | 4 | 5 | 6 | |
---|---|---|---|---|---|---|---|
FID (l/s) | 10 | 18 | 26 | 34 | 42 | 50 | |
Power (W)* | 2.5 | 3 | 4 | 5 | 7 | 13 | |
Floor Area up to (m²) | 30m² | 55m² | 80m² | 100m² | 130m² | 150m² | |
dB(A) @ 3m | 19 | 23 | |||||
*add 500w for heater version |
Dimensions
A | B (depth) | C | Weight |
---|---|---|---|
438 | 411 | 379 | 11.5kg |
Typical Specifications
Supply and install a PoziDry positive pressure loft unit for whole-house condensation control as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX. Telephone:0844 8560590. The unit should be mounted in the loft space with a diffuser in self-extinguishing ABS positioned at the top of the stairwell. The unit should meet all EMC and low voltage directives. The unit should include a filter with up to 5 ear maintenance intervals. And an integral time elapse meter. A tamper-proof cover to prevent casual interference in the running of the unit should cover the switch. The unit should revert to the selected setting.